4-14 SANnet II 200 FC, SATA, and SATA SE Array Installation, Operation, and Service Manual March 2005
Figure 4-9 Front Bezel and Front Bezel Locks of an Array
1. Use the provided key to unlock both bezel locks.
2. Grasp the front bezel cover on both sides and pull it forward and then down.
3. Remove the plastic cap from the left ear of the array.
a. Squeeze both sides of the cap at the top and the bottom.
b. Turn the cap toward the center of the array until it disengages and pull it free.
Caution – To avoid damage to the cap, do not pull the cap forward directly or pull
from only its top or bottom.
The ID switch is exposed when you remove the plastic cap.
Figure 4-10 ID Switch Located on the Left Front Side of Arrays and Expansion
Units
4. Press the upper or lower switch button to change the ID number so that each connected
RAID array and expansion unit uses a different loop ID.
Caution – The loop ID should only be changed while the expansion unit is powered
off or not in use. After changing the loop ID, a power cycle is required to make the ID
switch change take effect. Failure to cycle the power following a loop ID change can
lead to unexpected results.
The default ID switch setting for RAID arrays is 0. The default range of available
drive IDs for RAID arrays is 0 to 11 for 12 drives (the IDs 12–15 are ignored). The
default ID switch setting for expansion units and JBODs is 1.
Bezel locks
Plastic “ear” cap covering loop ID switch
Press to change the ID number